{"product_id":"polilag-closed-cell-drain-lagging-100mm-x-10m-x-5mm-roll-m1323","title":"Polilag Closed Cell Drain Lagging — 100mm x 10m x 5mm Roll | M1323","description":"\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003ePolilag closed cell polyethylene lagging is designed for wrapping stormwater and sanitary drain pipe where they penetrate concrete slabs and footings, allowing the pipe to move independently of the surrounding concrete as required by AS2870-2011. Unlike traditional open cell lagging, Polilag's closed cell construction is non-absorbent, so it won't soak up moisture over time and compromise the pipe's ability to move freely under the slab.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003eThe lagging is compression resistant and durable enough to handle the demands of a concrete pour without collapsing around the pipe, and it's straightforward to fit around pipes and fittings of varying sizes and shapes. Each roll runs 10 metres long, giving good coverage across multiple penetrations on a single job.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\" style=\"width: 100%; height: 166.844px;\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eSpec\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" style=\"width: 80.9306%; height: 19.6055px;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003ePolilag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eProduct Code\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003eM1323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003e100mm x 10m x 5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003eClosed cell, non-absorbent polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003eComplies with AS2870-2011 slab and footing lagging requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eEmissions\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003eCETEC emissions test certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6055px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 19.6055px;\"\u003eBarcode\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 19.6055px;\"\u003e9348099001302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 16.8152%; height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\" style=\"width: 80.9306%; height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eClosed cell, non-absorbent construction — won't hold water against the pipe\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eCompression resistant, tough and durable through the concrete pour\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eAllows pipe movement through the slab per AS2870-2011 Clause 5.6.4(a)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003ePrevents water penetration under the slab\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eFits easily around pipes and fittings of different sizes\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003eEmissions test certified (CETEC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eCompliance note:\u003c\/strong\u003e AS2870-2011 specifies a minimum lagging thickness of 20mm on Class H1\/H1-D sites and 40mm on Class H2\/H2-D and Class E\/E-D sites — worth a spec callout so tradies pick the right thickness\/diameter for the site classification, since this SKU is 100mm diameter at 5mm wall thickness.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eWhat is Polilag used for?\u003c\/em\u003e\u003cbr\u003ePolilag is a closed cell drain lagging used to wrap stormwater and sanitary pipe where it passes through concrete slabs and footings, allowing the pipe to move independently of the concrete as required by AS2870-2011.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eWhat size roll does it come in?\u003c\/em\u003e\u003cbr\u003eEach roll is 100mm wide, 10 metres long, and 5mm thick.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eHow is Polilag different from traditional lagging?\u003c\/em\u003e\u003cbr\u003eTraditional open cell lagging can absorb water and lose its ability to let the pipe move freely under the slab. Polilag's closed cell, non-absorbent construction avoids this, keeping the lagging effective for the life of the slab.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eWhat lagging thickness do I need for my site?\u003c\/em\u003e\u003cbr\u003eAS2870-2011 requires a minimum of 20mm lagging thickness on Class H1\/H1-D sites, and 40mm on Class H2\/H2-D and Class E\/E-D sites. Check your site classification before selecting a wrap thickness.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eDoes Polilag meet emissions requirements?\u003c\/em\u003e\u003cbr\u003eYes, Polilag is CETEC emissions test certified.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\"\u003e\u003cem\u003eDoes it come in bulk packs?\u003c\/em\u003e\u003cbr\u003eYes, Polilag is supplied 10 rolls per carton.\u003c\/p\u003e","brand":"Plumber Supplies Australia","offers":[{"title":"Default Title","offer_id":47559221411989,"sku":"M1323","price":19.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0563\/2373\/5701\/files\/polilag.png?v=1783909853","url":"https:\/\/www.plumbersupplies.com.au\/products\/polilag-closed-cell-drain-lagging-100mm-x-10m-x-5mm-roll-m1323","provider":"Plumber Supplies Australia","version":"1.0","type":"link"}