The usual way to stop a stormwater or drainage outlet flooding back into the system at high tide or heavy flow is a cast concrete headwall with an iron flap gate bolted into it. It works, but it's a concrete pour, a cast-in fitting and a fair bit of lead time before the outlet's actually protected.
There's a lighter way to do the same job. Fernco's HDPE flap valves bolt to an existing headwall or slide straight onto the pipe spigot — no grout, no cast-in fitting, no waiting on concrete to cure.
This post covers the two mounting styles — the wall mounted flap valve and the spigot mounted flap valve — and when to reach for each one.
What a Flap Valve Does
A flap valve sits at the discharge end of a stormwater or drainage line. Flow out of the pipe pushes the flap open; backflow or a rising tide on the outside pushes it shut. It's a one-way gate at the point the pipe meets open water or a channel, protecting everything upstream from flooding back.
Both styles here are HDPE: lightweight, corrosion resistant and UV stable, which matters for a fitting that lives outdoors in the weather, often partly submerged, for years without attention.
Wall Mounted: When There's a Headwall to Bolt To
The wall mounted flap valve fits to the outlet of a pipe or culvert at a headwall — the concrete or masonry structure the pipe discharges through. The frame mounts straight onto the wall face, and a mounting kit is supplied with each valve.
Because the frame sits flush against the wall, there's no grout needed between frame and wall to get a seal — it's a direct bolt-up. That's the detail that saves time on a headwall retrofit compared with casting a flap gate in from the start: the headwall can already exist, and you're adding the valve afterwards.
Sizes run from 100mm to 600mm, which covers everything from a small yard drain outlet to a sizeable stormwater culvert.
Spigot Mounted: When There's No Headwall
The spigot mounted version does the same job without needing a wall at all. It slides straight onto the end of the outlet pipe — the spigot — so it suits a pipe that simply terminates in open ground, a channel or a bank, with no structure to bolt a frame to.
Sizes run from 100mm to 630mm. If you're retrofitting backflow protection onto an existing pipe outlet that was never built with a headwall, this is the one to check first rather than planning a concrete structure just to carry a wall mounted valve.
Picking Between Them
- Headwall already there, or going in as part of the job: wall mounted flap valve, bolted to the face.
- Pipe just discharges into open ground, a channel or a bank, no headwall: spigot mounted flap valve, slid onto the pipe end.
- Size: wall mounted covers 100–600mm; spigot mounted covers 100–630mm. Match to the outlet pipe's actual outside diameter, not just the nominal size.
Low Cracking Head
Both styles are described as having a low cracking head — the amount of head pressure needed to lift the flap and let flow out. A valve with a high cracking head can back up a drainage line under light flow, which defeats the purpose on a system that's meant to be free-draining most of the time. A low cracking head means the flap opens readily under normal discharge and only holds shut against genuine backflow or tidal pressure.
Build Quality
Both valves are HDPE throughout — frame and flap — rather than the traditional cast iron flap gate. That trades some weight and rigidity for corrosion resistance, UV stability and a lot less maintenance: no rust, no seized hinge, no repainting. The listings describe both as low maintenance once fitted, which matters for an outlet that's often hard to get back to for servicing.
Not the Fitting for Every Backflow Job
These two are for the discharge end of a pipe — at a headwall or a bare spigot in open ground. If what you're actually protecting is a manhole further upstream from sewer or stormwater backing up into a property, that's the Fernco NRV retrofit non-return valve, which fits into an existing manhole on the outgoing pipe instead of at an open-water outlet.
And if the job is a single floor waste that keeps letting odours and insects back up through the riser, that's a different fitting again — see the Fernco Drain Seal. Three similar-sounding jobs, three different fittings for three different points in the system.
Compliance Note
Neither listing publishes a specific product certification number for these flap valves. Treat them as general drainage backflow/tidal protection fittings, confirm sizing against your design flow, and check with your local council or water authority on any outlet or backflow requirements that apply to the specific discharge point — requirements for stormwater outlets to waterways can vary by authority.
Wrap-Up
Choose the wall mounted flap valve where there's a headwall to bolt to, and the spigot mounted flap valve where the pipe just terminates in open ground. Both sit in our Fernco Flap & Non-Return Valves collection, part of the broader Fernco range.
Both are stocked on a continue-selling basis — confirm current lead times with PSA, especially on the larger sizes, before you lock in an install date.
Frequently Asked Questions
What's the difference between the wall mounted and spigot mounted flap valves?
The wall mounted valve bolts to an existing headwall face with a supplied mounting kit and no grout needed. The spigot mounted valve slides straight onto the end of the outlet pipe and doesn't need a headwall at all.
Do I need a headwall to fit a Fernco flap valve?
Not necessarily. If there's no headwall, use the spigot mounted version, which fits directly onto the pipe spigot in open ground or a channel.
Will a flap valve stop tidal water backing up at high tide?
Both styles are designed to close against backflow, which includes tidal ingress at an outlet. Confirm the size matches your pipe and check local requirements for tidal and stormwater outlets with your council or water authority.
What's the difference between a flap valve and the Fernco NRV?
A flap valve sits at the open-water discharge end of a pipe, at a headwall or spigot. The Fernco NRV is a retrofit non-return valve fitted inside an existing manhole further upstream, protecting a property from sewer or stormwater backing up — a different point in the system entirely.