The usual way to tie a new lateral into a sewer or stormwater main is to order a factory junction that matches the main's exact size and material, or break out a section of pipe and refit a tee. Either way you're waiting on a part, digging further than you need to, or hoping the precast junction someone speced three months ago still matches what's actually in the ground.
There's a quicker way. A compression or elastomeric saddle cores straight into the side of an existing main and seals around the hole, so one saddle covers a range of main sizes instead of needing a separate factory fitting for each one. No glue, no concrete, no weather delay.
This post runs through three Fernco fittings that do this job in different situations: the FA Uni Saddle for concrete and clay mains, the PA Uni Saddle for plastic mains, and the QwikSeal for service connections into profile and corrugated pipe or a manhole wall.
What These Fittings Do
All three let you connect a new lateral, or a service pipe, into an existing main without replacing a section of it. You core a hole in the main at the right spot, fit the saddle or seal over it, and connect your lateral pipe on the other side.
They're not interchangeable. Which one you reach for depends on what the main is made of and whether you're branching off the side of a pipe or dropping a service into a manhole.
FA Uni Saddle: Concrete and Clay Mains
The FA Uni Saddle is built for tying a lateral into a concrete or clay (vitrified earthenware) sewer or stormwater main, from DN250 right up to DN1500. That's a wide main-size range covered by one fitting family, instead of a different junction for every diameter on the drawing.
Branch sizes are 150mm or 200mm, which covers most house and small commercial lateral connections. The seal is EPDM rubber clamped down with 316 stainless steel band and fittings, so it's not relying on a gasket alone to hold the joint under ground movement.
Core the main, fit the saddle, tighten the stainless bands and connect the lateral. It's a genuine alternative to waiting on a factory junction cast for that exact main size, particularly useful on older concrete and clay mains where the as-built size doesn't always match the plan.
PA Uni Saddle: Plastic Mains
The PA Uni Saddle does the same job on structured wall, twinwall and smooth wall plastic sewer and stormwater mains, from DN300 to DN600, with a 160mm branch. A PA saddle adaptor is available if you need a different lateral size than the standard 160mm branch.
Because it clamps onto the pipe rather than relying on a factory-moulded junction, you're not locked into a particular plastic main brand or wall profile to make the connection work. That matters on plastic stormwater and sewer mains, where structured and twinwall profiles vary between manufacturers.
No adhesives, sealant or concrete are needed, and because there's no cure time, the install isn't held up waiting on weather the way a cast-in-place junction can be.
QwikSeal: Service Connections and Manhole Entries
The QwikSeal is a different style of fitting again. Instead of clamping onto the outside of the main, it forms a compression seal where a PVC service pipe passes into a solid wall, profile, closed-profile or corrugated main, or into a manhole wall.
It takes up to 7 degrees of deflection, which gives you some room to work with if the service pipe doesn't line up perfectly square to the entry point. Sizes cover 100mm, 150mm and 200mm service connections, and the listing describes it as suited to new, existing and rehabilitated sanitary and stormwater lines.
Use the QwikSeal where you're bringing a service into a main or manhole rather than branching off the side of a pipe run — the two jobs look similar on paper but call for different fittings.
Picking the Right One on Site
- Main is concrete or clay, 150mm or 200mm lateral: FA Uni Saddle.
- Main is structured, twinwall or smooth wall plastic, 160mm lateral: PA Uni Saddle (plus adaptor if the lateral size differs).
- Bringing a 100–200mm PVC service into a profile or corrugated main, or into a manhole wall: QwikSeal.
Either way, confirm the main's actual material and outside profile before you core — these fittings only help if you've correctly identified what's really in the ground first.
Build Quality
The FA and PA Uni Saddles use EPDM rubber seals with 316 stainless steel bands and fittings — a sealing material and fastener combination chosen for buried, wet service rather than general-purpose hardware. The QwikSeal's compression seal is designed specifically to handle the kind of minor misalignment you get connecting a straight service pipe into a corrugated or profiled wall.
None of the three need adhesive, grout or a curing period, which is what makes them fast to fit compared with a cast-in or glued connection.
Before You Cut Into a Live Main
Cutting into an existing, in-service main is usually something your water authority or council wants to know about or approve first — requirements vary by authority and by whether it's a private line or a reticulated asset. Confirm approval steps before coring, separately from getting the fitting right.
The main size, branch size and deflection figures above are from Fernco's own specifications; check the current product listing before ordering, since ranges can be updated.
Wrap-Up
Three different jobs, three different fittings: the FA Uni Saddle for concrete and clay mains, the PA Uni Saddle for plastic mains, and the QwikSeal for service and manhole entries. All three sit in our Fernco Saddles & Branch Connections collection, alongside the rest of the Fernco range for drainage repairs and transitions.
All three are stocked on a continue-selling basis, so check current lead times with PSA before you commit to a connection date on site.
Frequently Asked Questions
What's the difference between the FA and PA Uni Saddles?
The FA Uni Saddle is for concrete and clay mains (DN250–DN1500, 150mm or 200mm branch). The PA Uni Saddle is for structured, twinwall and smooth wall plastic mains (DN300–DN600, 160mm branch). Match the saddle to the main material, not just the size.
Can I use a QwikSeal to branch off the side of a main like a saddle does?
No. The QwikSeal forms a compression seal where a service pipe passes into a main or manhole wall — it's for service connections and manhole entries, not for branching off the side of a pipe run the way the FA and PA saddles do.
Do I need council or water authority approval to cut into an existing main?
Usually yes, though requirements vary by authority and by whether the main is a private line or a reticulated asset. Confirm with the relevant water authority or council before coring into a live main, separately from choosing the right fitting.
How much misalignment can the QwikSeal take up?
Up to 7 degrees of deflection, according to the product listing, which gives some tolerance if the service pipe isn't perfectly square to the entry point.